  • 1
  • 2
  • 3

Brand Name : MECHAN

Model Number : PLA301

Certification : CE, ISO13485

Place of Origin : CHINA

MOQ : Negotiation

Price : Negotiation

Payment Terms : T/T, L/C

Supply Ability : 100000 sets per year

Packaging Details : carton

Operating Mode : Ablation & Coagulation

Output Energy : Adjustable

Application : Cervical and Lumbar

Advantage : Minimally Invasive, Low Temperature

Color : Gray White

Weight : 7Kg

Contact Now

Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery

Product Introduction

MECHAN Orthoepedic Plasma Surgery System PLA-800 are designed to operate in urology field, it includes both ablation and coagulation modes, which result in different tissue effects. It is widely applying to spine and joints treatment.

Product Diagram

CE Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery

Product Character

• Establishes a plasma layer quickly and efficiently
• Maintains a stable and aggressive plasma layer
• Maximizes the size of the plasma layer

Technical Parameter

Input Volts

198-240V 50Hz

100-120V 60Hz

Export device could convert automatically per customer requirements

Output Power

Ablation or resection: ≤351W

Coagulation or hemostasis: ≤111W

Working Frequency 100 KHz ± 10%
Dimension 405*440*130mm (L*W*H)
Working Mode

Ablation and resection: level 1-10

Coagulation: level 1-10

Weight 7.0kg

Product Advanatages

  • Safety: multi-polar design, change the traditional way that current flow through human body
  • Low Temperature: 40 to 70 centigrade during operation, decrease the thermal damage to around normal tissue
  • Precise cutting: the thin plasma layer make precise cutting becoming true, and it will not hurt the around normal tissue
  • Speedy cutting: cutting and coagulation at the same time, no need to change the probe frequently, saving operation time
  • Shorten recovery period: less hurt to human body, recovery faster

System Set Up

1). One tabletop generator device

2). One reusable and non-sterile power supply cable.

3). One reusable and non-sterile footswitch.

4). One reusable and non-sterile treatment handle which is for foot control.

5). Treatment probes.

Description Remark
Manufacturer Logo MECHEN Brand.
Pads Insulation and support on the surface.
Receptacle of Footswitch Connects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment Handle Connects with the treatment accessories.
Power Switch System start power button. “O” means power off; “I” means power on.
ABLATION mode Selector Select ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe Connection LED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch Connection LED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down Button The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

Anesthesia


Epidural anesthesia is usually used. You can also choose spinal anesthesia or general anesthesia.

Storage Condition

This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:

1. Temperature: -40℃~+55℃;

2. Relative humidity: ≤90%;

3. Atmospheric pressure: 50kPa~106kPa

CE Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery


Product Tags:

low temperature probe

      

spinal wand

      
Cheap CE Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery for sale

CE Procise Plasma Wand Spine Probe Minimally Invasive Plasma Surgery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chengdu Mechan Electronic Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)