Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery

  • 1
  • 2
  • 3

Brand Name : MECHAN

Model Number : PLA303

Certification : CE, ISO13485

Place of Origin : CHINA

MOQ : Negotiation

Price : Negotiation

Payment Terms : T/T, L/C

Supply Ability : 100000 sets per year

Packaging Details : carton

Ablation : Adjustable from 1 to 10

Coagulation : Adjustable from 1 to 10

Application : Turbinate Channeling and Ablation

Advantage : Minimally Invasive, Low Temperature

Warranty : 2 years after sterilization

Shaft Length : 110mm

Usage : Ablation, Cutting, Resection, Hemostasis

Feature : Disposable

Contact Now

ENT Probe for Turbinate Channeling Minimally Invasive Plasma Surgery

Product Introduction

PLA303 is design specially for turbinate channeling. It is a tri-polar wand and connect with PLA-700 ENT plasma surgery system. PLA303 has adult and kids choices. It has the function of cutting, ablation, hemostasis and coagulation.

Product Tip Picture

Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery

Product Character

Three-stage probe (front and back poles), one and two poles punch, and three poles ablate and stop bleeding. The cprobe is used for punching, cutting, ablation, and hemostasis. It conforms to ergonomic principles and is mainly used for turbinate perforation and ablation. Applying to Inferior turbinate hypertrophy with mucosal hypertrophy

Product Advanatages

  • Safety: Compared with traditional surgical methods (such as: electric knife, laser), the current does not flow through the human body, the working surface temperature is only 40 ° C to 70 ° C, and the surrounding tissue is less thermally damaged. When used in the recommended energy range, the cutting and ablation depth is controlled to ≤50μm.
  • Minimally Invasive: Compared with traditional surgical methods (such as electric knife, laser), it has less heat, reduces tissue thermal damage, reduces wound healing time, reduces wound bleeding and scar formation
  • High Efficiency: Compared with traditional surgical methods (such as: electric knife, laser), the patient's pain during surgery is significantly reduced, and the incidence of postoperative inflammation is significantly reduced. During the surgery, the doctor stops bleeding while cutting, and does not need other hemostasis tools.

System Set Up

Description Remark
Manufacturer Logo MECHEN Brand.
Working Frequency 50Hz
Receptacle of Footswitch Connects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment Handle Connects with the treatment accessories.
Power Switch System start power button. “O” means power off; “I” means power on.
ABLATION mode Selector Select ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe Connection LED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch Connection LED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down Button The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

Anesthesia

Local infiltration anesthesia

Cutting Principle

Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.

Treatment Diseases

Turbinate channeling

Storage Condition

Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.

Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery


Product Tags:

ent surgical instruments

      

portable plasma wand

      
Cheap Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery for sale

Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chengdu Mechan Electronic Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)